AC/DC Switching Adapter
AC/DC Switching Adapter
Product ID: 5 Watt Series
Switching Power Adapter 5 watt series, from 3.3V to 15V, USA/ Japan/ Taiwan/ Europe /UK /Australia plug available. With safety approvals, CEC, DoE Level VI, Energy Star, ErP Stage 2, NRCan and GEMS Level VI certified and RoHS compliance
Features:
* 100-240VAC Universal Input
* Single Output to 5W
* Regulated Output with Low Ripple Noise
* Safety Agency Requirements and EMI/EMS Certified
* Private Label Marking Available
* Modified and Custom Design Available
* 1 Year Warranty
Green Mode |
CEC, DoE Level VI, Energy Star, ErP Stage 2, NRCan & GEMS Level VI |
No Load Power Consumption Less Than 0.1W |
Model |
O/P Voltage |
O/P Current |
Watt |
ATS005-W033U/E/B/A |
3.3V |
1.50A |
4.95W |
ATS005-W050U/E/B/A |
5.0V |
1.00A |
5.00W |
ATS005-W051U/E/B/A |
5.0V |
1.50A |
7.50W |
ATS005-W060U/E/B/A |
5.9V |
1.20A |
7.08W |
ATS005-W075U/E/B/A |
7.5V |
1.00A |
7.50W |
ATS005-W090U/E/B/A |
9.0V |
0.67A |
6.03W |
ATS005-W120U/E/B/A |
12.0V |
0.60A |
7.20W |
ATS005-W150U/E/B/A |
15.0V |
0.50A |
7.50W |
Input |
Voltage |
100-240 VAC |
Line Frequency |
50-60Hz |
Current |
0.19A Max. |
Protection |
Internal Primary Current Fuse, Inrush Limiting |
Configuration |
U for US Plug/ JP Plug |
E for EU Plug |
B for UK Plug |
A for AU Plug |
Output |
Load Regulation |
± 5% (Typical) |
Ripple |
1~2% Vp-p Max. for Output Voltage@ Full Load |
Transient Response |
0.5mS for 50% Load Change Typical |
Holdup Time |
10mS @ Full Load |
Protection |
Short Circuit Protection/ Over Voltage Protection/ Over Current
Protection |
DC Cord |
22AWG / 20AWG / 18AWG |
Ferrite Core |
Yes |
Safety Approvals |
|
For USA - CB / UL / cUL / FCC / PSE / BSMI / LPS |
|
For Europe - CB / CE / LPS |
|
For UK - CB / CE / LPS |
|
For Australia - CB / RCM / LPS |
Electrical |
Topology |
Switching Flyback |
Dielectric Withstand |
3000 VAC Primary - Secondary |
Leakage Current |
0.25mA |
Efficiency |
DoE Level VI, Energy Star, ErP Stage 2, NRCan & GEMS Level VI Certified
|
EMI Conduction & Radiation |
Compliance to EN55022 Class B |
Harmonic Current |
Compliance to EN61000-3-2,3 |
EMS Immunity |
Compliance to IEC61000-4-2,3,4,5,6,8,11 |
MTBF |
300,000 Calculated Hours at 25°C, by Telcordia SR-332 |
Environmental |
Operaturing Temperature |
0 to +40°C |
Storage Temperature |
-20 to +80°C |
Relative Humidity |
Operating: 20 to 80% RH |
Storage: 10 to 90% RH |
Cooling |
Natural Convection Cooling |
Mechanical |
Case Dimension |
U - L 59 x W 43 x H 25 (mm) |
E - L52 x W 28 x H 60 (mm) |
B - L 51 x W 49 x H 48 (mm) |
A - L 52 x W 41 x H 50 (mm) |
Weight |
U:82g / E:96g / B:100g / A:94g (Ref.) |
|
Order Information:
- Minimum Order: Negotiable
- OEM/ODM Product, Branded Product, Buyer's Label Offered
- FOB: HK